Inorganic
1041Nitrite
The health basis on which the EPA sets this contaminant's legal limit. Reported verbatim from the regulatory record — it is not a diagnosis or a prediction about any individual.
Causes methemoglobinemia in infants; acutely dangerous. Removed only by reverse osmosis (NSF 58), not carbon filters.
- Maximum contaminant level
- 1 mg/LLegal MCLEnforceable federal limit
- Health goal
- 1 mg/LHealth goal (MCLG)No known health risk
- Category
- InorganicCategory
- Reporting unit
- mg/LReporting unit
Nitrate/nitrite cannot be removed by standard carbon-based pitcher, faucet, or under-sink filters (NSF/ANSI 42 or 53). Only reverse-osmosis systems certified to NSF/ANSI 58 (or specific ion-exchange systems) are effective. Standard carbon filters will NOT protect against this contaminant.
Regulatory basis
How Nitrite is regulated
What the enforceable limit actually obliges a utility to do, and how it differs from the health-based goal it is measured against.
For Nitrite the enforceable limit and the health goal are the same number, 1 mg/L. EPA set the Maximum Contaminant Level (MCL) at the health goal (MCLG), so there is no feasibility gap here: meeting the legal limit also means meeting the health-based goal. A value above 1 mg/L is both an exceedance of the goal and a violation of the enforceable standard.
Results are reported in mg/L. A laboratory result and the limits above are only comparable when both are expressed in that same unit — a value in a different unit will be off by orders of magnitude. WaterQualityLens groups Nitrite under Inorganic for navigation; the grouping is ours, the limits are the regulator’s.
The record for Nitrite
- Enforceable limit (MCL)
- 1 mg/L
- Health goal (MCLG)
- 1 mg/L
- Reporting unit
- mg/L
- Category
- Inorganic
- Contaminant code
- 1041
Limits as published by EPA and state primacy agencies. This page reports regulatory and certification records; it does not assess anyone’s exposure and makes no health prediction.
Certification scope
Which certifications actually remove Nitrite
Only NSF/ANSI 53, 58 and 401 are health-contaminant standards. A product certified only to Standard 42 (aesthetics) or 372 (lead-free materials) has not been verified to reduce Nitrite, however the box is worded.
NSF/ANSI 53
Counts — health standardHealth effects: lead, VOCs, cysts, chromium, and (post-P473) PFAS reduction.
No filter in our registry holds a verified NSF/ANSI 53 claim for Nitrite, and Standard 53 covers carbon-based reduction, which does not remove Nitrite. Reverse osmosis certified to NSF/ANSI 58 is the treatment that applies here.
NSF/ANSI 58
Counts — health standardReverse osmosis: dissolved inorganics, arsenic, hexavalent chromium, and total PFAS.
3 filters in our registry hold an independently verified NSF/ANSI 58 claim for Nitrite, listed below.
NSF/ANSI 401
Counts — health standardEmerging/incidental compounds: pharmaceuticals and select trace contaminants.
No filter in our registry holds a verified NSF/ANSI 401 claim for Nitrite. That means we hold no certification record — not that the standard could never cover it.
NSF/ANSI 42
Does not count — not a health standardAesthetic effects: chlorine, taste, odor, particulates. No health-contaminant protection.
No registry product lists Nitrite under NSF/ANSI 42. It would not count as verification of Nitrite reduction in any case.
NSF/ANSI 372
Does not count — not a health standardLead-free materials (manufacturing content only). Not a water-treatment claim.
No registry product lists Nitrite under NSF/ANSI 372. It would not count as verification of Nitrite reduction in any case.
Counts are of active products in the WaterQualityLens filter registry holding a verified claim for contaminant code 1041 under that standard, as recorded by the certifying body (NSF, WQA, or IAPMO). Certification is granted per contaminant, not per product: a filter certified to Standard 53 for one contaminant is not thereby certified for Nitrite.
Certified reduction · commercial placements
Filters verified to reduce Nitrite
These filters hold an independent NSF/ANSI health certification (Standard 53, 58, or 401) specifically for Nitrite. Certification against a health standard means an accredited lab verified the filter reduces this contaminant — a materials-only claim such as NSF 42 or 372 does not.
- Verified PartnerFrizzlife
M800 Under-Sink Reverse Osmosis
FZ-M800Under-sink RO$399NSF/ANSI 58Certified by NSF
- Verified PartnerAquaTru
Classic Countertop RO
AT-CLASSICCountertop RO$449NSF/ANSI 58Certified by NSF
- Verified PartnerWaterdrop
G3P800 Under-Sink RO
WD-G3P800Under-sink RO$549NSF/ANSI 58Certified by NSF