Skip to content
WaterQualityLens

Microbiological

3100

Total Coliform

Indicates possible sewage or animal-waste contamination and potential pathogens.

Maximum contaminant level
0.0 MPN
Legal MCL
Enforceable federal limit
Health goal
0.0 MPN
Health goal (MCLG)
No safe exposure level
Category
Microbiological
Category
Reporting unit
MPN
Reporting unit

Regulatory basis

How Total Coliform is regulated

What the enforceable limit actually obliges a utility to do, and how it differs from the health-based goal it is measured against.

For Total Coliform both the enforceable limit and the health goal are 0. There is no permissible band: any confirmed detection is, by definition, an exceedance, which is why microbiological results are reported as present/absent rather than as a concentration to be compared against a threshold.

Results are reported in MPN. A laboratory result and the limits above are only comparable when both are expressed in that same unit — a value in a different unit will be off by orders of magnitude. WaterQualityLens groups Total Coliform under Microbiological for navigation; the grouping is ours, the limits are the regulator’s.

The record for Total Coliform

Enforceable limit (MCL)
0
Health goal (MCLG)
0
Reporting unit
MPN
Category
Microbiological
Contaminant code
3100

Limits as published by EPA and state primacy agencies. This page reports regulatory and certification records; it does not assess anyone’s exposure and makes no health prediction.

Certification scope

Which certifications actually remove Total Coliform

Only NSF/ANSI 53, 58 and 401 are health-contaminant standards. A product certified only to Standard 42 (aesthetics) or 372 (lead-free materials) has not been verified to reduce Total Coliform, however the box is worded.

  • NSF/ANSI 53

    Counts — health standard

    Health effects: lead, VOCs, cysts, chromium, and (post-P473) PFAS reduction.

    No filter in our registry holds a verified NSF/ANSI 53 claim for Total Coliform. That means we hold no certification record — not that the standard could never cover it.

  • NSF/ANSI 58

    Counts — health standard

    Reverse osmosis: dissolved inorganics, arsenic, hexavalent chromium, and total PFAS.

    No filter in our registry holds a verified NSF/ANSI 58 claim for Total Coliform. That means we hold no certification record — not that the standard could never cover it.

  • NSF/ANSI 401

    Counts — health standard

    Emerging/incidental compounds: pharmaceuticals and select trace contaminants.

    No filter in our registry holds a verified NSF/ANSI 401 claim for Total Coliform. That means we hold no certification record — not that the standard could never cover it.

  • NSF/ANSI 42

    Does not count — not a health standard

    Aesthetic effects: chlorine, taste, odor, particulates. No health-contaminant protection.

    No registry product lists Total Coliform under NSF/ANSI 42. It would not count as verification of Total Coliform reduction in any case.

  • NSF/ANSI 372

    Does not count — not a health standard

    Lead-free materials (manufacturing content only). Not a water-treatment claim.

    No registry product lists Total Coliform under NSF/ANSI 372. It would not count as verification of Total Coliform reduction in any case.

Counts are of active products in the WaterQualityLens filter registry holding a verified claim for contaminant code 3100 under that standard, as recorded by the certifying body (NSF, WQA, or IAPMO). Certification is granted per contaminant, not per product: a filter certified to Standard 53 for one contaminant is not thereby certified for Total Coliform.

Certified reduction · commercial placements

Filters verified to reduce Total Coliform

These filters hold an independent NSF/ANSI health certification (Standard 53, 58, or 401) specifically for Total Coliform. Certification against a health standard means an accredited lab verified the filter reduces this contaminant — a materials-only claim such as NSF 42 or 372 does not.

No filter in our registry currently holds an independent NSF/ANSI health certification specifically for Total Coliform. For contaminants without a certified point-of-use option, treatment at the utility level or a physical lab test is the appropriate next step.

Hardware links are affiliate placements marked “Verified Partner.” Products appear here solely because they hold an independently verified NSF/ANSI health certification for Total Coliform; commercial arrangements never affect this list.